Page 29 - Fisica In Medicina n° 2/2017
P. 29
=5. Martin CJ and Sookpeng S, "Setting up computed tomography automatic tube current modulation systems", (2016), 36(3), J. Radiol. Prot (2016), pp. R74-R956. www3.gehealthcare.co.uk7. http://www.gafchromic.com8. Brady S, Yoshizumi T, Toncheva G, Frus D., "Implementation of radiochromic film dosimetryprotocol for volumetric dose assessments to various organs during diagnostic CT procedures", MedPhys. (2010),37(9), pp. 4782-92.9. Sookpeng S, Butdee C, "Signal-to-noise ratio and dose to the lens of the eye for computedtomography examination of the brain using an automatic tube current modulation system",EmergRadiol (2016), pp. 1–710. Kanal KM, Stewart BK, Kolokythas O and Shuman WP, "Impact of Operator-Selected ImageNoise Index and Reconstruction Slice Thickness on Patient Radiation Dose in 64-MDCT", AJR(2007), 189, pp. 219–22511. Rampado O, Garelli E, Deagostini S and Ropolo R, "Dose and energy dependence of response ofGafchromic XR-QA film for kilovoltage x-ray beams", Phys. Med. Biol (2006), (51), pp. 2871–288112. Tomic N, Quintero C, Whiting BR, Aldelaijan S, Bekerat H, Liang L, DeBlois F, Seuntjens J,Devic S, "Characterization of calibration curves and energy dependence GafChromicTM XR-QA2model based radiochromic film dosimetry system", Med Phys. (2014), 41(6), pp. 062105-1 - 913. Di Lillo F, Mettivier G., Sarno A, Tromba G, Tomic N, Devic S and Russo P, "Energy dependent calibration of XR-QA2 radiochromic film with monochromatic and polychromatic x-ray beam",Med. Phys. (2016) 43, 58314. Rampado O, Garelli E, Ropolo R, "Computed tomography dose measurements with radiochromicfilms and a flatbed scanner", Med Phys. (2010),37(1), pp. 189-9615. Giaddui T, Cui Y, Galvin J, Yu Y, Xiao Y, "Characteristics of Gafchromic XRQA2 films for kVimage dose measurement", Med Phys. (2012), 39(2), pp. 842-85016. Asero G, Greco C, Gueli AM, Raffaele L and Spampinato S. Evaluation of spatial resolution inimage acquisition by optical flatbed scanners for radiochromic film dosimetry. J Instrum. (2016),11,pp. P0302417. Schindera ST, Nelson RC, Toth TL, Nguyen GT, Toncheva GI, DeLong DM, Yoshizumi TT,"Effect of patient size on radiation dose for abdominal MDCT with automatic tube currentmodulation: phantom study", AJR Am J Roentgenol. (2008), 190(2), pp. W100-518. Israel GM, Cicchiello L, Brink J, Huda W, "Patient Size and Radiation Exposure in Thoracic, Pelvic, and Abdominal CT Examinations Performed With Automatic Exposure Control", AJR(2010), 195, pp. 1342–1346============^q`j=20


































































































   27   28   29   30   31